methylbenzene gear flow measurement

Date:2017-01-20 source:

  methylbenzene gear flow measurement  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow Meter CO.,LTD use advanced scientific managementas a means, relying on Shanghai’s advantages as a key science and educationcity in the country, it has fully utilized resources and actively cooperatedwith Shanghai Jiaotong University, Shanghai’s Fudan University and otheruniversities, and had some achievement, especially in super micro flow,ovalgear flow meter ,coriolis mass flowmeter,electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump. In the past year,ourcompany had establish the reliable and lasting research cooperation with ChineseAcademy of Sciences, Peking University, Norwegian University and other researchinstitutes.Now company is involved in polyurethane, fuel consumption,automotive, dispensing robots, semiconductors, odorizing equipment, batteries,electricity, telecommunications, petroleum, chemical, coal, metallurgy, waterconservancy, food, medical, machinery and other industries. In futuredevelopment, Shanghai JSN should enlarge and strengthen our company, leadinginto the ranks of companies with international competitiveness, and strive tocreate an international, green, sustainable development of instrumentationcompany.

 methylbenzene gear flow measurement

methylbenzene gear flow measurement

At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.

TheCX-M and G-series mirco flow meters are the world"s new volumetric flowmetersintroduced by BASF in 2011. Since its establishment, the CX-M oval gear flowmeter and the G-series mirco flow meters have been selling well in the marketfor more than 100,000 units a year since they were sold. The third generationlaunched in 2017, with more than 90% accuracy and stability, won thecertification of the National Bureau of Metrology. The quality and reliabilityof Shanghai JiShen instruments need not worry. According to the statistics ofChina Instrument Association, Deep flow meter reliability has always beenranked in the top 3, especially in the long-term statistics failure rate is farbelow the industry average, deep advocate "the best after-sales service isno service", but also achieved a continuous three years without qualitycomplaints .

gear flow measurement

methylbenzene gear flow measurement

Ovalgear flow meter Through the rotation of the gear cavity, through a series ofdeceleration and speed ratio adjustment mechanism, directly connected with theindicator on the instrument panel, and through the mechanical counter for thetotal display. Or remote display is mainly through The decelerated gear drivesthe permanent magnet to rotate so that the contacts of the spring relay (Hallsensor) are closed or opened synchronously at the same rotation frequency asthe permanent magnet, thereby sending one electric pulse to the other displayinstrument.

 methylbenzene gear flow measurement

methylbenzene gear flow measurement

Maintechnical data of JSN micro oval Oval gear flow meter

CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"

CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"

CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"

CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"

CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"

CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"

CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"


What is the reason why the tiny gauge flow meter is larger than the actual value? the reason:1. The flow has a large pulse.2. The medium is mixed with gas.3. Medium viscosity is too large.Treatment measures:1. Reduce the pulsation of the flow in the pipeline.2. Install degasifier.3. Recalibrate, replace the adjustment gear pair and correct it.